{"id":16729,"date":"2016-01-01T10:00:19","date_gmt":"2016-01-01T17:00:19","guid":{"rendered":"http:\/\/www.miridiatech.com\/news\/?p=16729"},"modified":"2016-11-01T04:39:49","modified_gmt":"2016-11-01T10:39:49","slug":"acugraph-5-video-training-setting-up-your-acugraph","status":"publish","type":"post","link":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/","title":{"rendered":"AcuGraph 5 Video Training: Setting up your AcuGraph"},"content":{"rendered":"<h2><b>Setting Up Your AcuGraph<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">5 Most Important Things you need to know to get started using your AcuGraph.<\/span><\/p>\n<p><iframe loading=\"lazy\" src=\"https:\/\/player.vimeo.com\/video\/161546090\" width=\"640\" height=\"360\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<ol>\n<li>\n<h3><b><b>How to Setup AcuGraph Hardware: <\/b><\/b><\/h3>\n<p><span style=\"font-weight: 400;\">This is the AcuGraph Processing Unit &#8211; it\u2019s the brain, heart, and soul of AcuGraph. This is what takes the measurements and sends them to the\u00a0AcuGraph software.<\/span><\/li>\n<\/ol>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/small_488993.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16736\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/small_488993-300x184.jpg\" alt=\"small_488993\" width=\"300\" height=\"184\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/small_488993-300x184.jpg 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/small_488993.jpg 384w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">To set this up, you\u2019ll notice that there\u2019s a plug on either end.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Plug.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-16739 alignnone\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Plug-300x149.png\" alt=\"Plug\" width=\"300\" height=\"149\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">One plug is for the usb cable that goes to the computer, the other plug is for your probe and ground bar.<\/p>\n<p style=\"padding-left: 30px;\">To set up your wires, the side of the unit that has the white plug connector is for the USB cable. The square USB plug is inserted here and the other end (flat) of the USB cable goes to your computer.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.35.59-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16740\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.35.59-PM-292x300.png\" alt=\"usb cable\" width=\"292\" height=\"300\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.35.59-PM-292x300.png 292w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.35.59-PM-768x789.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.35.59-PM-997x1024.png 997w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.35.59-PM-660x678.png 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.35.59-PM.png 1316w\" sizes=\"auto, (max-width: 292px) 100vw, 292px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">The black plug on the other side of the AcuGraph unit is for your probe cables. This is\u00a0the black and grey twin cable, both coming out of the same black square plug.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.37.51-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16741\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.37.51-PM-242x300.png\" alt=\"grey and white cable\" width=\"242\" height=\"300\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.37.51-PM-242x300.png 242w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.37.51-PM-768x953.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.37.51-PM-825x1024.png 825w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.37.51-PM-660x819.png 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.37.51-PM.png 1172w\" sizes=\"auto, (max-width: 242px) 100vw, 242px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">Once\u00a0both of these cables are plugged into the hardware unit, you can set it in a convenient place for use.<\/p>\n<p style=\"padding-left: 30px;\">Now some of you may have received this unit, the graphing station with your AcuGraph purchase.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16742\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station-300x201.jpg\" alt=\"Graphing-Station\" width=\"300\" height=\"201\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station-300x201.jpg 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station-768x515.jpg 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station-660x443.jpg 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station.jpg 1000w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">The graphing station is designed to hold all of your AuGraph equipment in one spot for your convenience while you\u2019re using it.<\/p>\n<p style=\"padding-left: 30px;\">Let\u2019s set that up\u2026<\/p>\n<p style=\"padding-left: 30px;\">First you see that there\u2019s a rectangular cutout where the Acugraph fits snuggly and securely so it won\u2019t fall off at the table or the desk. You want that in there so that the probe plug (the black and grey wires) are coming off the table toward you where you\u2019re going to use them.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.49.29-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16743\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.49.29-PM-300x194.png\" alt=\"Screen Shot AG 1\" width=\"300\" height=\"194\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.49.29-PM-300x194.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.49.29-PM-768x498.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.49.29-PM-1024x664.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.49.29-PM-660x428.png 660w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">Insert the black probe and silver ground bar into\u00a0the two holes in the taller part of the graphing station for convenience to hold these at an angle toward you.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.55.15-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16746\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.55.15-PM-300x251.png\" alt=\"Screen Shot AG 2\" width=\"300\" height=\"251\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.55.15-PM-300x251.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.55.15-PM-768x643.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.55.15-PM-1024x858.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.55.15-PM-660x553.png 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.55.15-PM.png 1626w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">This tube includes supplies that will be conveniently used with your graphing station.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.57.39-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16745\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.57.39-PM-300x274.png\" alt=\"Screen Shot AG3\" width=\"300\" height=\"274\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.57.39-PM-300x274.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.57.39-PM-768x701.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.57.39-PM-1024x935.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.57.39-PM-660x603.png 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.57.39-PM.png 1500w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">In\u00a0that tube, you\u2019ll find there are some white blotter pads for getting the excess moisture off the probe.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.59.31-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16747\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.59.31-PM-300x167.png\" alt=\"Screen Shot AG4\" width=\"300\" height=\"167\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.59.31-PM-300x167.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.59.31-PM-768x427.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.59.31-PM-1024x569.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.59.31-PM-660x367.png 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-6.59.31-PM.png 1378w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">And there are plastic cups designed to hold the water that you will use to moisten the probe tip.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.02.09-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16748\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.02.09-PM-300x152.png\" alt=\"Screen Shot AG5\" width=\"300\" height=\"152\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.02.09-PM-300x152.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.02.09-PM-768x388.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.02.09-PM-1024x517.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.02.09-PM-660x333.png 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.02.09-PM.png 1774w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">In the larger, slanted floor area, you can store the\u00a0extra probe tips. These are standard cotton swab ends that have been cut to length for the probe. To replenish your supply you can buy these at any drug store and cut your own tips, or you can purchase more pre-cut from our website.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.04.09-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16749\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.04.09-PM-300x157.png\" alt=\"Screen Shot AG6\" width=\"300\" height=\"157\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.04.09-PM-300x157.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.04.09-PM-768x402.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.04.09-PM-1024x536.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.04.09-PM-660x345.png 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.04.09-PM.png 1468w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">And once your graphing station is setup, or you have made other setup arrangements for AcuGraph,\u00a0take a cotton swab end and insert\u00a0it on your probe, as you see in the red circle, below.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/AG6.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16752\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/AG6-300x186.jpg\" alt=\"AG6\" width=\"300\" height=\"186\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/AG6-300x186.jpg 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/AG6.jpg 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">Once inserted, moisten the cotton tip with water and dab off any excess water on the blotter pad or a nearby towel. You want the probe tip to be wet, but not dripping. Your equipment is now ready to take measurements.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/moisten-probe.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-16751\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/moisten-probe-300x83.png\" alt=\"moisten-probe\" width=\"300\" height=\"83\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/moisten-probe-300x83.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/moisten-probe.png 400w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<h3 style=\"padding-left: 30px;\">2.\u00a0<strong>Performing the AcuGraph Exams<\/strong><\/h3>\n<p style=\"padding-left: 30px;\">Have\u00a0the patient hold the silver ground bar in one hand. Which hand they use does not matter, and the patient needs to maintain contact with the ground bar, but does not need to squeeze\u00a0it.<\/p>\n<p style=\"padding-left: 30px;\">\u00a0<a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.37.46-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16753\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.37.46-PM-300x206.png\" alt=\"Screen Shot 2016-05-10 at 7.37.46 PM\" width=\"300\" height=\"206\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.37.46-PM-300x206.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.37.46-PM-768x528.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.37.46-PM-1024x704.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.37.46-PM-660x454.png 660w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">Take your probe and make sure you have a clean cotton tip inserted in the gold sleeve. Moisten the cotton tip in the water for 2-3 seconds and tap it on the moisture pad few\u00a0times to remove the\u00a0excess water. <em>(When you take a measurement you want it to leave a small wet spot but you don\u2019t want a droplet of water dripped or running across the skin.)<\/em><\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.44.45-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16754\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.44.45-PM-300x200.png\" alt=\"Screen Shot 2016-05-10 at 7.44.45 PM\" width=\"300\" height=\"200\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.44.45-PM-300x200.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.44.45-PM-768x512.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.44.45-PM-1024x682.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.44.45-PM-660x440.png 660w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">With the probe tip moistened, follow the prompts on the screen. Take note to place the probe perpendicular to the skin rather than at an\u00a0angle. Do not apply extra pressure with the probe,\u00a0the weight of the probe is sufficient to capture a reading and is easily standardized across measurements.<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.50.39-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16755\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.50.39-PM-300x235.png\" alt=\"Screen Shot 2016-05-10 at 7.50.39 PM\" width=\"300\" height=\"235\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.50.39-PM-300x235.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.50.39-PM-768x602.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.50.39-PM-1024x802.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.50.39-PM-660x517.png 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-7.50.39-PM.png 1866w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">At the end of the reading, you\u2019ll hear that it gives you a double beep audio tone to let you know that your reading was captured and the software\u00a0announces the next point for you to measure. Move to that next point and repeat the process.<\/p>\n<p style=\"padding-left: 30px;\"><em>Tip: If you notice that the reading is kind of low at a certain point, you can move the cotton tip across the skin, looking for a higher reading because you might not be on the right point. The electrical location of the points may by slightly different than the traditional anatomical location, and when you find the correct location, you will notice based on the elevated reading. Just follow the software point-by-point and you should have great results<\/em>.<\/p>\n<p style=\"padding-left: 30px;\">One other thing to keep in mind, as you get started it\u2019s going to require some practice and so your first five or ten graphs you should\u00a0ask somebody to help you out. Friends, family members or employees work great for this, and will allow you to practice a little bit. Pay special attention to\u00a0finding the points, moving around slightly to get the highest readings, and\u00a0moving\u00a0from point to point throughout the exam. It is common to ask the patient to switch hands with the ground bar when you are ready to start measuring the other hand, and they can choose whichever hand is most comfortable while measurements are performed on their feet.<\/p>\n<p style=\"padding-left: 30px;\">Once you have completed\u00a0five or ten graphs, you should be ready to complete good quality exams.<\/p>\n<h3 style=\"padding-left: 30px;\">3. <strong>Remeasuring to track results in AcuGraph<\/strong><\/h3>\n<p style=\"padding-left: 30px;\">Now that you\u2019ve completed your first graph with AcuGraph, let\u2019s talk about one of the primary source of confusion new users run into so we can\u00a0help you avoid it.<\/p>\n<p style=\"padding-left: 30px;\">People who are very excited with their new equipment often share that after they\u2019ve taken their probe and they\u2019ve done their first graph, and then they immediately do another graph on the same person just to see if it gives the same result twice. Well it doesn\u2019t.<\/p>\n<p style=\"padding-left: 30px;\">Here\u2019s the thing\u2026<\/p>\n<p style=\"padding-left: 30px;\"><a href=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-8.14.15-PM.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-16756\" src=\"http:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-8.14.15-PM-300x300.png\" alt=\"Screen Shot 2016-05-10 at 8.14.15 PM\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-8.14.15-PM-300x300.png 300w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-8.14.15-PM-150x150.png 150w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-8.14.15-PM-768x768.png 768w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-8.14.15-PM-1024x1024.png 1024w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-8.14.15-PM-660x660.png 660w, https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Screen-Shot-2016-05-10-at-8.14.15-PM.png 1424w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"padding-left: 30px;\">When you take a measurement, you\u2019re actually putting a small electric current right into that acupuncture point and that small electric current travels through\u00a0the meridian. That\u2019s actually how we\u2019re able to get a measurement of how well the meridian is conducting electricity. But the act of\u00a0taking the measurement makes two important changes physiologically:<\/p>\n<p style=\"padding-left: 30px;\">1. There\u2019s a change right at the point where you measure. It creates a charge from the electric current in the skin. This is\u00a0called an &#8216;ionic gradient&#8217; and that ionic gradient can persist for minutes or even hours. So it changes the point that\u2019s measured therefore, when you go remeasure you\u2019ll find out that the point has changed because you measured it.<\/p>\n<p style=\"padding-left: 30px;\">2. When you measure you are putting a small electrical current through the meridians. When you put that through the meridians it changes the meridian itself. Therefore, it really takes a complete horary cycle, a full 24 hours, for the channels to re-balance and\u00a0settle back down again. If you measure and remeasure right away, you\u2019ll find that the results are different. You changed the system by measuring it. This is expected.<\/p>\n<h4 style=\"padding-left: 30px;\"><strong>So, how does re-measurement work correctly? <\/strong><\/h4>\n<p style=\"padding-left: 30px;\">When you measure today and treat the patient based on the results of that measurement, give the patient time for the treatment to take effect. At their next visit,\u00a0say in two days, measure again and compare the results of that measurement with the original measurement from the first visit. How did the patient respond to your treatment? Results may be good or bad, and you should use this information to adjust your treatment plans for each subsequent treatment. Some patients will respond better, faster than other patients. Repeat this re-measurement at the beginning of each visit. As you go through several visits you\u2019ll see considerable consistent patterns that develop. <strong>And in that consistent pattern, you\u2019ll also see how it begins to change and improve with time as you treat.\u00a0<\/strong><\/p>\n<p style=\"padding-left: 30px;\">Hopefully, this resolves concerns or confusions you have about whether the measurements are consistent. They will be when you consistently measure over the course of several days and multiple visits.<\/p>\n<h3 style=\"padding-left: 30px;\">4.\u00a0<strong>Re-measuring \u201cSplit\u201d Meridians\u00a0<\/strong><strong>in AcuGraph<\/strong><\/h3>\n<p style=\"padding-left: 30px;\">Now that we&#8217;ve covered the appropriate way to complete re-measurements for an entire exam, it&#8217;s important that we talk about re-measuring specific points at the conclusion of an exam. This is called re-measuring &#8220;Split&#8221; Meridians, and is one of the most important features of AcuGraph. When\u00a0you\u2019ve completed a graph, the computer will analyze the readings you have captured and can help identify points where you may have missed the reading location. Theses show up as &#8220;Split&#8221; readings, and the software will prompt you to re-measure these points right away.<\/p>\n<p style=\"padding-left: 30px;\">At first this\u00a0may be confusing because it\u2019s asking you to immediately remeasure something you just measured. (And, I&#8217;ve just told you not to re-measure!)<\/p>\n<p style=\"padding-left: 30px;\">Allow me to\u00a0explain it a little bit\u2026<\/p>\n<p style=\"padding-left: 30px;\">A split is what you find when the measurement on one side (right)\u00a0compared to the measurement from the\u00a0the other side (left) of the same channel is very different. Normally the two sides are going to be similar. When you have a split, there\u2019s a major difference between the two sides. The most common cause of this is a missed point location on one side of the body. Acupuncture points will always have a higher reading than the surrounding skin. That\u2019s how you can locate acupuncture point with your probe.\u00a0<strong>If you\u2019ve missed the point during the reading, then you\u2019ll have a low reading on the side where you missed the point. <\/strong><\/p>\n<p style=\"padding-left: 30px;\">Therefore, you may end up with a graph that has a split for that particular meridian.<\/p>\n<p style=\"padding-left: 30px;\">The software will prompt you to re-measure that point,\u00a0but <strong>only on the low side<\/strong>\u00a0because you might have missed the point there. So if you go back and remeasure that side and you get a higher reading, sure enough you missed the point the first time and now you\u2019ve gotten the correct reading. This new reading is the one that it uses. If you go back and remeasure that side and you don\u2019t have the reading come up to match the other side,\u00a0that is a true \u201cSplit\u201d and that needs to be treated. The software will help you identify that.<\/p>\n<p style=\"padding-left: 30px;\">So, in summary, it\u2019s okay to go back and re-measure splits because you\u2019re only re-measuring the low reading to see if point location was off.\u00a0This is why the re-measure \u201cSplit\u201d feature is so important. It makes your readings more accurate, provides more accurate treatment recommendations\u00a0and gives you a better outcome all the way around.<\/p>\n<p style=\"padding-left: 30px;\">You&#8217;re all set &#8211; it&#8217;s time to start practicing&#8230;<\/p>\n<p style=\"padding-left: 30px;\">Welcome to AcuGraph!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Setting Up Your AcuGraph 5 Most Important Things you need to know to get started using your AcuGraph. How to Setup AcuGraph Hardware: This is the AcuGraph Processing Unit &#8211;&#8230;<\/p>\n","protected":false},"author":3,"featured_media":16742,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":true,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[6,31,3,1437],"tags":[],"class_list":["post-16729","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-acugraph-4","category-products","category-practice","category-video-training"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>AcuGraph 5 Video Training: Setting up your AcuGraph<\/title>\n<meta name=\"description\" content=\"5 Most Important Things you need to know to get started using your AcuGraph...Now some of you may have received this unit, the graphing station...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"AcuGraph 5 Video Training: Setting up your AcuGraph\" \/>\n<meta property=\"og:description\" content=\"5 Most Important Things you need to know to get started using your AcuGraph...Now some of you may have received this unit, the graphing station...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/\" \/>\n<meta property=\"og:site_name\" content=\"Acupuncture Technology News\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/pages\/AcuGraph\/336708131507\" \/>\n<meta property=\"article:published_time\" content=\"2016-01-01T17:00:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-11-01T10:39:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i2.wp.com\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station.jpg?fit=1000%2C671&ssl=1\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"671\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Dr. Adrian Larsen\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@AcuGraph\" \/>\n<meta name=\"twitter:site\" content=\"@AcuGraph\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dr. Adrian Larsen\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/\"},\"author\":{\"name\":\"Dr. Adrian Larsen\",\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/#\\\/schema\\\/person\\\/6dcdab9e977505c3a48b656aace6ca74\"},\"headline\":\"AcuGraph 5 Video Training: Setting up your AcuGraph\",\"datePublished\":\"2016-01-01T17:00:19+00:00\",\"dateModified\":\"2016-11-01T10:39:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/\"},\"wordCount\":1819,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/Graphing-Station.jpg\",\"articleSection\":[\"AcuGraph\",\"Products\",\"Tips\\\/Techniques\",\"Video Training\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/\",\"url\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/\",\"name\":\"AcuGraph 5 Video Training: Setting up your AcuGraph\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/Graphing-Station.jpg\",\"datePublished\":\"2016-01-01T17:00:19+00:00\",\"dateModified\":\"2016-11-01T10:39:49+00:00\",\"description\":\"5 Most Important Things you need to know to get started using your AcuGraph...Now some of you may have received this unit, the graphing station...\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/Graphing-Station.jpg\",\"contentUrl\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/Graphing-Station.jpg\",\"width\":1000,\"height\":671},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/2016\\\/01\\\/acugraph-5-video-training-setting-up-your-acugraph\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"AcuGraph 5 Video Training: Setting up your AcuGraph\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/#website\",\"url\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/\",\"name\":\"Acupuncture Technology News\",\"description\":\"Ancient acupuncture with modern tools.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/#organization\",\"name\":\"Miridia Technology Inc.\",\"url\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i1.wp.com\\\/www.miridiatech.com\\\/news\\\/wp-content\\\/uploads\\\/2016\\\/10\\\/2011-M-Logo-Rebuild_Large_Dark.png?fit=1000%2C427&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i1.wp.com\\\/www.miridiatech.com\\\/news\\\/wp-content\\\/uploads\\\/2016\\\/10\\\/2011-M-Logo-Rebuild_Large_Dark.png?fit=1000%2C427&ssl=1\",\"width\":1000,\"height\":427,\"caption\":\"Miridia Technology Inc.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/pages\\\/AcuGraph\\\/336708131507\",\"https:\\\/\\\/x.com\\\/AcuGraph\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/miridiatech\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/#\\\/schema\\\/person\\\/6dcdab9e977505c3a48b656aace6ca74\",\"name\":\"Dr. Adrian Larsen\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7a85af461a4e9a47826d6df138cdfa35aec0602d1d82448c86f2e47ae0bd5850?s=96&d=wavatar&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7a85af461a4e9a47826d6df138cdfa35aec0602d1d82448c86f2e47ae0bd5850?s=96&d=wavatar&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7a85af461a4e9a47826d6df138cdfa35aec0602d1d82448c86f2e47ae0bd5850?s=96&d=wavatar&r=g\",\"caption\":\"Dr. Adrian Larsen\"},\"description\":\"Adrian P. Larsen, D.C., F.A.S.A., C.Ac. Dr. Adrian P. Larsen is the President and Founder of Miridia Technology, where he combines his expertise in acupuncture and technology to develop innovative tools that help practitioners deliver better care and improve patient outcomes. Passionate about blending traditional healing wisdom with modern technology, Dr. Larsen has played a key role in advancing electroacupuncture and digital meridian analysis for practitioners around the world. Dr. Larsen and his wife are enjoying a new season of life as most of their seven children are now grown and married, and they are the proud grandparents of five grandchildren.\",\"sameAs\":[\"http:\\\/\\\/www.miridiatech.com\"],\"url\":\"https:\\\/\\\/www.miridiatech.com\\\/news\\\/author\\\/adrian\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"AcuGraph 5 Video Training: Setting up your AcuGraph","description":"5 Most Important Things you need to know to get started using your AcuGraph...Now some of you may have received this unit, the graphing station...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/","og_locale":"en_US","og_type":"article","og_title":"AcuGraph 5 Video Training: Setting up your AcuGraph","og_description":"5 Most Important Things you need to know to get started using your AcuGraph...Now some of you may have received this unit, the graphing station...","og_url":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/","og_site_name":"Acupuncture Technology News","article_publisher":"http:\/\/www.facebook.com\/pages\/AcuGraph\/336708131507","article_published_time":"2016-01-01T17:00:19+00:00","article_modified_time":"2016-11-01T10:39:49+00:00","og_image":[{"width":1000,"height":671,"url":"https:\/\/i2.wp.com\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station.jpg?fit=1000%2C671&ssl=1","type":"image\/jpeg"}],"author":"Dr. Adrian Larsen","twitter_card":"summary_large_image","twitter_creator":"@AcuGraph","twitter_site":"@AcuGraph","twitter_misc":{"Written by":"Dr. Adrian Larsen","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/#article","isPartOf":{"@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/"},"author":{"name":"Dr. Adrian Larsen","@id":"https:\/\/www.miridiatech.com\/news\/#\/schema\/person\/6dcdab9e977505c3a48b656aace6ca74"},"headline":"AcuGraph 5 Video Training: Setting up your AcuGraph","datePublished":"2016-01-01T17:00:19+00:00","dateModified":"2016-11-01T10:39:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/"},"wordCount":1819,"commentCount":0,"publisher":{"@id":"https:\/\/www.miridiatech.com\/news\/#organization"},"image":{"@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/#primaryimage"},"thumbnailUrl":"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station.jpg","articleSection":["AcuGraph","Products","Tips\/Techniques","Video Training"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/","url":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/","name":"AcuGraph 5 Video Training: Setting up your AcuGraph","isPartOf":{"@id":"https:\/\/www.miridiatech.com\/news\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/#primaryimage"},"image":{"@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/#primaryimage"},"thumbnailUrl":"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station.jpg","datePublished":"2016-01-01T17:00:19+00:00","dateModified":"2016-11-01T10:39:49+00:00","description":"5 Most Important Things you need to know to get started using your AcuGraph...Now some of you may have received this unit, the graphing station...","breadcrumb":{"@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/#primaryimage","url":"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station.jpg","contentUrl":"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station.jpg","width":1000,"height":671},{"@type":"BreadcrumbList","@id":"https:\/\/www.miridiatech.com\/news\/2016\/01\/acugraph-5-video-training-setting-up-your-acugraph\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.miridiatech.com\/news\/"},{"@type":"ListItem","position":2,"name":"AcuGraph 5 Video Training: Setting up your AcuGraph"}]},{"@type":"WebSite","@id":"https:\/\/www.miridiatech.com\/news\/#website","url":"https:\/\/www.miridiatech.com\/news\/","name":"Acupuncture Technology News","description":"Ancient acupuncture with modern tools.","publisher":{"@id":"https:\/\/www.miridiatech.com\/news\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.miridiatech.com\/news\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.miridiatech.com\/news\/#organization","name":"Miridia Technology Inc.","url":"https:\/\/www.miridiatech.com\/news\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.miridiatech.com\/news\/#\/schema\/logo\/image\/","url":"https:\/\/i1.wp.com\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/10\/2011-M-Logo-Rebuild_Large_Dark.png?fit=1000%2C427&ssl=1","contentUrl":"https:\/\/i1.wp.com\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/10\/2011-M-Logo-Rebuild_Large_Dark.png?fit=1000%2C427&ssl=1","width":1000,"height":427,"caption":"Miridia Technology Inc."},"image":{"@id":"https:\/\/www.miridiatech.com\/news\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/pages\/AcuGraph\/336708131507","https:\/\/x.com\/AcuGraph","https:\/\/www.youtube.com\/user\/miridiatech"]},{"@type":"Person","@id":"https:\/\/www.miridiatech.com\/news\/#\/schema\/person\/6dcdab9e977505c3a48b656aace6ca74","name":"Dr. Adrian Larsen","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/7a85af461a4e9a47826d6df138cdfa35aec0602d1d82448c86f2e47ae0bd5850?s=96&d=wavatar&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7a85af461a4e9a47826d6df138cdfa35aec0602d1d82448c86f2e47ae0bd5850?s=96&d=wavatar&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7a85af461a4e9a47826d6df138cdfa35aec0602d1d82448c86f2e47ae0bd5850?s=96&d=wavatar&r=g","caption":"Dr. Adrian Larsen"},"description":"Adrian P. Larsen, D.C., F.A.S.A., C.Ac. Dr. Adrian P. Larsen is the President and Founder of Miridia Technology, where he combines his expertise in acupuncture and technology to develop innovative tools that help practitioners deliver better care and improve patient outcomes. Passionate about blending traditional healing wisdom with modern technology, Dr. Larsen has played a key role in advancing electroacupuncture and digital meridian analysis for practitioners around the world. Dr. Larsen and his wife are enjoying a new season of life as most of their seven children are now grown and married, and they are the proud grandparents of five grandchildren.","sameAs":["http:\/\/www.miridiatech.com"],"url":"https:\/\/www.miridiatech.com\/news\/author\/adrian\/"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/www.miridiatech.com\/news\/wp-content\/uploads\/2016\/05\/Graphing-Station.jpg","jetpack_shortlink":"https:\/\/wp.me\/pA5CI-4lP","jetpack_sharing_enabled":true,"jetpack_likes_enabled":true,"_links":{"self":[{"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/posts\/16729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/comments?post=16729"}],"version-history":[{"count":12,"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/posts\/16729\/revisions"}],"predecessor-version":[{"id":18037,"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/posts\/16729\/revisions\/18037"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/media\/16742"}],"wp:attachment":[{"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/media?parent=16729"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/categories?post=16729"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.miridiatech.com\/news\/wp-json\/wp\/v2\/tags?post=16729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}